{"id":770,"date":"2026-06-25T03:27:33","date_gmt":"2026-06-25T03:27:33","guid":{"rendered":"https:\/\/vasozk.com\/?page_id=770"},"modified":"2026-07-01T13:00:31","modified_gmt":"2026-07-01T13:00:31","slug":"pcs-current-probe-for-energy-storage-and-battery-inverter-testing","status":"publish","type":"page","link":"https:\/\/vasozk.com\/es\/application\/pcs-current-probe-for-energy-storage-and-battery-inverter-testing\/","title":{"rendered":"Sonda de corriente PCS para pruebas de almacenamiento de energ\u00eda e inversores de bater\u00eda."},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"770\" class=\"elementor elementor-770\" data-elementor-settings=\"{&quot;element_pack_global_tooltip_width&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_padding&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true}}\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce1b54d e-con-full e-flex e-con e-parent\" data-id=\"ce1b54d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e6e6a9 elementor-widget elementor-widget-html\" data-id=\"8e6e6a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<!DOCTYPE html>\r\n<html lang=\"en\">\r\n<head>\r\n<meta charset=\"UTF-8\">\r\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\r\n<title>PCS Current Probe for Energy Storage &amp; Battery Inverter | VASO<\/title>\r\n<style>\r\n*{margin:0;padding:0;box-sizing:border-box}\r\nbody{font-family:Arial,sans-serif;color:#555;line-height:1.8}\r\n.container{max-width:1200px;margin:0 auto}\r\n.section{padding:80px 60px}\r\n.label{font-size:14px;letter-spacing:3px;text-transform:uppercase;color:rgb(10,31,59);font-weight:600;margin-bottom:10px;display:block}\r\n.h1{font-size:48px;font-weight:600;color:#1a1a2e;margin-bottom:8px;line-height:1.2}\r\n.h1-sub{font-size:22px;font-weight:400;color:rgb(10,31,59);margin-bottom:20px;line-height:1.3}\r\n.h2{font-size:38px;font-weight:600;color:#1a1a2e;margin-bottom:30px;line-height:1.3}\r\n.h3{font-size:24px;font-weight:600;color:#1a1a2e;margin-bottom:20px}\r\n.p-lead{font-size:20px;color:rgb(10,31,59);font-weight:500;margin-bottom:30px}\r\n.p-body{font-size:16px;color:#555;line-height:1.85;max-width:900px;margin-bottom:20px}\r\n.divider{height:2px;width:100%;background:rgb(10,31,59);max-width:1200px;margin:0 auto}\r\n.card{background:#fff;border-radius:15px;padding:50px 40px;box-shadow:0 0 5px 3px rgba(0,0,0,.08)}\r\n.card-icon{font-size:48px;margin-bottom:20px;color:rgb(10,31,59)}\r\n.grid-2{display:grid;grid-template-columns:1fr 1fr;gap:40px}\r\n.checklist{list-style:none;padding:0;margin:0}\r\n.checklist li{font-size:15px;color:#555;line-height:1.8;margin-bottom:14px;padding-left:25px;position:relative}\r\n.checklist li::before{content:'\\2713';position:absolute;left:0;color:rgb(10,31,59);font-weight:bold}\r\n.btn-primary{display:inline-block;padding:15px 40px;background:rgb(10,31,59);color:#fff;text-decoration:none;border-radius:8px;font-weight:500;font-size:16px;transition:background .3s}\r\n.btn-primary:hover{background:#0d2548}\r\n.btn-outline{display:inline-block;padding:15px 40px;background:transparent;color:rgb(10,31,59);text-decoration:none;border:2px solid rgb(10,31,59);border-radius:8px;font-weight:500;font-size:16px;transition:all .3s}\r\n.btn-outline:hover{background:rgb(10,31,59);color:#fff}\r\ntable{width:100%;border-collapse:collapse;margin-top:20px;border-radius:12px;overflow:hidden;box-shadow:0 0 5px 3px rgba(0,0,0,.05)}\r\ntable thead th{text-align:left;padding:18px 24px;background:rgb(10,31,59);color:#fff!important;font-size:16px;font-weight:600}\r\ntable td{padding:16px 24px;border-bottom:1px solid #e8e8e8;font-size:15px;color:#1a1a2e;background:#fff}\r\n.faq-item{margin-bottom:30px}\r\n.faq-q{font-size:18px;font-weight:600;color:#1a1a2e;margin-bottom:10px}\r\n.faq-a{font-size:15px;color:#555;line-height:1.85}\r\n.model-card{text-align:center;padding:40px 30px}\r\n.model-card .model-name{font-size:20px;font-weight:700;color:#1a1a2e;margin-bottom:8px}\r\n.model-card .model-fit{font-size:14px;color:rgb(10,31,59);font-weight:600;margin-bottom:10px}\r\n.model-card .model-reason{font-size:14px;color:#777;line-height:1.6}\r\n.hero-img{width:100%;height:auto;border-radius:15px;box-shadow:0 0 10px 4px rgba(0,0,0,.1);margin-bottom:40px;display:block}\r\n.highlight-box{background:rgb(10,31,59);color:#fff;padding:40px 50px;border-radius:15px;text-align:center;margin-top:40px}\r\n.highlight-box h3{color:#fff;font-size:22px}\r\n.highlight-box p{color:rgba(255,255,255,.85);font-size:15px;line-height:1.8}\r\n@media(max-width:768px){\r\n.grid-2{grid-template-columns:1fr}\r\n.section{padding:50px 30px}\r\n.h1{font-size:32px}\r\n.h2{font-size:28px}\r\n}\r\n<\/style>\r\n<\/head>\r\n<body>\r\n\r\n<!-- HERO -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\">\r\n<span class=\"label\">Solicitud<\/span>\r\n<h1 class=\"h1\">Sonda de corriente PCS para pruebas de almacenamiento de energ\u00eda e inversores de bater\u00eda.<\/h1>\r\n<p class=\"p-lead\">Mida la corriente bidireccional de los convertidores de potencia, la corriente del inversor de la bater\u00eda y las formas de onda de conversi\u00f3n de alta potencia con sondas de corriente CA\/CC estables dise\u00f1adas para pruebas de larga duraci\u00f3n.<\/p>\r\n<img decoding=\"async\" src=\"https:\/\/vasozk.com\/wp-content\/uploads\/2026\/07\/application-pcs.webp\" alt=\"Pruebas de almacenamiento de energ\u00eda\" class=\"hero-img\">\r\n<p class=\"p-body\">Las pruebas de los sistemas de almacenamiento de energ\u00eda PCS implican un flujo de potencia bidireccional, altos niveles de corriente y ciclos de prueba prolongados. Los errores de medici\u00f3n o el sobrecalentamiento de la sonda pueden retrasar la validaci\u00f3n y hacer que el an\u00e1lisis de la forma de onda no sea fiable.<\/p>\r\n<\/div>\r\n<\/section>\r\n\r\n<div class=\"divider\"><\/div>\r\n\r\n<!-- PAIN POINTS -->\r\n<section class=\"section\" style=\"background:#f8f9fa\">\r\n<div class=\"container\">\r\n<span class=\"label\">Puntos d\u00e9biles del sector<\/span>\r\n<h2 class=\"h2\">Desaf\u00edos en las pruebas de PCS y almacenamiento de energ\u00eda<\/h2>\r\n<p class=\"p-body\" style=\"margin-bottom:40px\">Las pruebas de los sistemas de almacenamiento de energ\u00eda PCS implican un flujo de potencia bidireccional, altos niveles de corriente y ciclos de prueba prolongados. Los errores de medici\u00f3n o el sobrecalentamiento de la sonda pueden retrasar la validaci\u00f3n y hacer que el an\u00e1lisis de la forma de onda no sea fiable.<\/p>\r\n<div class=\"grid-2\">\r\n<div class=\"card\"><div class=\"card-icon\">\u21c6<\/div><h3 class=\"h3\">Corriente bidireccional<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Gran corriente en el bus de CC y en el lado de la bater\u00eda durante las pruebas de carga y descarga.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83c\udf10<\/div><h3 class=\"h3\">Modos conectado a la red y modo aislado<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Formas de onda de corriente del inversor bidireccional en modos de funcionamiento conectados a la red y aislados de la red.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\u23f2<\/div><h3 class=\"h3\">Pruebas de larga duraci\u00f3n<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Medici\u00f3n de corriente de larga duraci\u00f3n durante pruebas t\u00e9rmicas, de envejecimiento y de resistencia.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83c\udf0a<\/div><h3 class=\"h3\">Captura de onda conmutada<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Es necesario capturar la ondulaci\u00f3n de conmutaci\u00f3n y los eventos transitorios, no solo la corriente RMS.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83c\udf21<\/div><h3 class=\"h3\">Tolerancia t\u00e9rmica<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Tolerancia limitada al calentamiento de la sonda, la deriva o la reducci\u00f3n de frecuencia en pruebas de alta corriente.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udcc8<\/div><h3 class=\"h3\">Retrasos en la validaci\u00f3n<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Los errores de medici\u00f3n pueden retrasar la validaci\u00f3n y hacer que el an\u00e1lisis de la forma de onda no sea fiable.<\/p><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- HOW IT HELPS -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\">\r\n<span class=\"label\">Soluci\u00f3n<\/span>\r\n<h2 class=\"h2\">C\u00f3mo ayudan las sondas ACP<\/h2>\r\n<p class=\"p-body\">Las sondas de la serie ACP proporcionan medici\u00f3n de corriente CA\/CC no invasiva para sistemas de conversi\u00f3n de alta potencia. Ayudan a los ingenieros de PCS a observar el comportamiento de la corriente sin interrumpir el recorrido del conductor, preservando los detalles de la forma de onda para la depuraci\u00f3n, el an\u00e1lisis de eficiencia y la validaci\u00f3n de la protecci\u00f3n.<\/p>\r\n<div class=\"grid-2\" style=\"margin-top:40px\">\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udd0b<\/div><h3 class=\"h3\">Cobertura de sistema completo<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Captura de las formas de onda de corriente del lado de la bater\u00eda, del bus de CC y del inversor.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udcc8<\/div><h3 class=\"h3\">Rango de alta corriente<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Admite pruebas de alta corriente desde \u00b11000 A hasta \u00b13000 A.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\u26a1<\/div><h3 class=\"h3\">Ancho de banda amplio<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Proporciona un ancho de banda de hasta 40 MHz CC con ACP1000 y de hasta 30 MHz CC con ACP3000.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83c\udf21<\/div><h3 class=\"h3\">Sin reducci\u00f3n de frecuencia<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Permite realizar pruebas de corriente m\u00e1xima a largo plazo sin reducci\u00f3n de frecuencia, bas\u00e1ndose en los datos del producto.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udd17<\/div><h3 class=\"h3\">Cableado simplificado<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Simplificaci\u00f3n del cableado de banco mediante la alimentaci\u00f3n directa del osciloscopio o la alimentaci\u00f3n por USB Tipo-C.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udcaa<\/div><h3 class=\"h3\">Sensor estable<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Estructura de sensor altamente estable y dif\u00edcil de da\u00f1ar.<\/p><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- RECOMMENDED MODELS -->\r\n<section class=\"section\" style=\"background:#f8f9fa\">\r\n<div class=\"container\">\r\n<span class=\"label\">Modelos recomendados<\/span>\r\n<h2 class=\"h2\">Elija la sonda PCS adecuada<\/h2>\r\n<div class=\"grid-2\">\r\n<div class=\"card model-card\"><div class=\"card-icon\">\ud83c\udfc6<\/div><div class=\"model-name\">ACP1000<\/div><div class=\"model-fit\">M\u00f3dulos PCS est\u00e1ndar, inversores de bater\u00eda y conversi\u00f3n de potencia media a alta<\/div><div class=\"model-reason\">Rango de \u00b11000 A y ancho de banda de CC a 40 MHz<\/div><\/div>\r\n<div class=\"card model-card\"><div class=\"card-icon\">\ud83d\udcaa<\/div><div class=\"model-name\">ACP3000<\/div><div class=\"model-fit\">Sistemas de almacenamiento a nivel de contenedor, bus de CC de alta corriente y grandes sistemas de conversi\u00f3n de energ\u00eda.<\/div><div class=\"model-reason\">Rango de \u00b13000 A y ancho de banda de CC a 30 MHz<\/div><\/div>\r\n<div class=\"card model-card\"><div class=\"card-icon\">\ud83d\udee0<\/div><div class=\"model-name\">Sonda de corriente CA\/CC personalizada<\/div><div class=\"model-fit\">Requisitos especiales para barras colectoras, armarios o plataformas de prueba<\/div><div class=\"model-reason\">Rango de corriente, ancho de banda, tama\u00f1o de mordaza y longitud del cable personalizados.<\/div><\/div>\r\n<\/div>\r\n<p style=\"font-size:15px;color:#888;margin-top:30px;text-align:center\">El ACP1000 es la opci\u00f3n preferida para la mayor\u00eda de las pruebas de inversores de bater\u00edas y sistemas de control de potencia (PCS). El ACP3000 se recomienda cuando el punto de medici\u00f3n puede superar los 1000 A o al probar sistemas de gran tama\u00f1o a nivel de armario el\u00e9ctrico.<\/p>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- TYPICAL TEST SCENARIOS -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\">\r\n<span class=\"label\">Escenarios de prueba<\/span>\r\n<h2 class=\"h2\">Escenarios de prueba t\u00edpicos<\/h2>\r\n<div class=\"grid-2\">\r\n<div class=\"card\"><ul class=\"checklist\"><li>Medici\u00f3n de la corriente de carga y descarga del lado de la bater\u00eda<\/li><li>Captura de la forma de onda de la corriente del bus de CC del PCS<\/li><li>Validaci\u00f3n de la corriente de salida del inversor conectado a la red<\/li><li>Pruebas de respuesta transitoria de convertidores bidireccionales<\/li><\/ul><\/div>\r\n<div class=\"card\"><ul class=\"checklist\"><li>Pruebas t\u00e9rmicas y de envejecimiento de armarios de almacenamiento de energ\u00eda<\/li><li>Verificaci\u00f3n de la l\u00f3gica de protecci\u00f3n durante eventos de sobrecorriente o sobretensiones de corta duraci\u00f3n.<\/li><li>An\u00e1lisis de la corriente de rizado para la evaluaci\u00f3n de filtros, condensadores e inductores.<\/li><\/ul><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- PARAMETERS -->\r\n<section class=\"section\" style=\"background:#f8f9fa\">\r\n<div class=\"container\">\r\n<span class=\"label\">Presupuesto<\/span>\r\n<h2 class=\"h2\">Par\u00e1metros y ventajas<\/h2>\r\n<table><thead><tr><th>Capacidad<\/th><th>Ventaja de la serie ACP<\/th><\/tr><\/thead><tbody>\r\n<tr><td>Rango actual<\/td><td>ACP1000: \u00b11000A; ACP3000: \u00b13000A<\/td><\/tr>\r\n<tr><td>Ancho de banda<\/td><td>ACP1000: CC\u201340 MHz; ACP3000: CC\u201330 MHz<\/td><\/tr>\r\n<tr><td>Exactitud<\/td><td>Valor t\u00edpico de \u00b11%, valor de garant\u00eda de \u00b13% seg\u00fan datos internos del producto.<\/td><\/tr>\r\n<tr><td>Fuente de alimentaci\u00f3n<\/td><td>Alimentaci\u00f3n directa del osciloscopio o alimentaci\u00f3n USB tipo C<\/td><\/tr>\r\n<tr><td>Pruebas a largo plazo<\/td><td>Admite pruebas de corriente m\u00e1xima a largo plazo basadas en datos del producto.<\/td><\/tr>\r\n<tr><td>reducci\u00f3n de frecuencia<\/td><td>No hay reducci\u00f3n de frecuencia de corriente m\u00e1xima basada en los datos del producto.<\/td><\/tr>\r\n<tr><td>Temperatura de funcionamiento<\/td><td>De -40 \u00b0C a +85 \u00b0C<\/td><\/tr>\r\n<tr><td>Estructura del sensor<\/td><td>Muy estable y dif\u00edcil de da\u00f1ar<\/td><\/tr>\r\n<\/tbody><\/table>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- KEY BENEFIT HIGHLIGHT -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\">\r\n<div class=\"highlight-box\">\r\n<h3>Sin reducci\u00f3n de frecuencia de corriente m\u00e1xima<\/h3>\r\n<p style=\"margin-top:12px\">A diferencia de muchas sondas de alta corriente que deben reducir su capacidad a frecuencias m\u00e1s altas, las sondas de la serie ACP admiten pruebas de corriente m\u00e1xima a largo plazo sin reducci\u00f3n de frecuencia, una ventaja fundamental para los programas de validaci\u00f3n t\u00e9rmica y de resistencia del almacenamiento de energ\u00eda.<\/p>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- FAQ -->\r\n<section class=\"section\" style=\"background:#f8f9fa\">\r\n<div class=\"container\">\r\n<span class=\"label\">Preguntas frecuentes<\/span>\r\n<h2 class=\"h2\">Preguntas frecuentes<\/h2>\r\n<div class=\"faq-item\"><p class=\"faq-q\">\u00bfQu\u00e9 sonda de corriente es la adecuada para realizar pruebas PCS?<\/p><p class=\"faq-a\">El ACP1000 es adecuado para la mayor\u00eda de las pruebas de m\u00f3dulos PCS e inversores de bater\u00eda. El ACP3000 se recomienda para buses de alta corriente, almacenamiento de energ\u00eda a nivel de contenedor y validaci\u00f3n de alta corriente.<\/p><\/div>\r\n<div class=\"faq-item\"><p class=\"faq-q\">\u00bfSe pueden utilizar las sondas ACP para la medici\u00f3n de corriente bidireccional?<\/p><p class=\"faq-a\">S\u00ed. Las sondas ACP est\u00e1n dise\u00f1adas para la medici\u00f3n de corriente CA\/CC, lo que las hace adecuadas para la corriente de carga y descarga, la corriente del inversor y la corriente de pulso en sistemas PCS bidireccionales.<\/p><\/div>\r\n<div class=\"faq-item\"><p class=\"faq-q\">\u00bfPor qu\u00e9 es importante el ancho de banda en la medici\u00f3n de corriente PCS?<\/p><p class=\"faq-a\">El ancho de banda afecta la precisi\u00f3n con la que la sonda captura la ondulaci\u00f3n, los componentes de conmutaci\u00f3n y los eventos transitorios. Para la depuraci\u00f3n de PCS, tanto el rango de corriente como el ancho de banda deben considerarse conjuntamente.<\/p><\/div>\r\n<div class=\"faq-item\"><p class=\"faq-q\">\u00bfLas sondas ACP permiten realizar pruebas de larga duraci\u00f3n?<\/p><p class=\"faq-a\">S\u00ed. Los datos del producto indican que las sondas de la serie ACP admiten pruebas de corriente m\u00e1xima a largo plazo sin reducci\u00f3n de la frecuencia de corriente m\u00e1xima.<\/p><\/div>\r\n<div class=\"faq-item\"><p class=\"faq-q\">\u00bfSe pueden personalizar la mordaza de la sonda o el cable para adaptarlos a los armarios?<\/p><p class=\"faq-a\">S\u00ed. Las versiones personalizadas permiten ajustar el tama\u00f1o de la mordaza, la longitud del cable, el rango de corriente, el ancho de banda y los requisitos de protecci\u00f3n en funci\u00f3n de las limitaciones del armario o la barra colectora.<\/p><\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- CTA -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\" style=\"text-align:center\">\r\n<h3 class=\"h3\" style=\"font-size:28px\">\u00bfListo para probar su PCS o sistema de almacenamiento de energ\u00eda?<\/h3>\r\n<p class=\"p-body\" style=\"max-width:800px;margin:0 auto 30px\">Contacte hoy mismo con VASO para hablar sobre sus necesidades de pruebas de sistemas de almacenamiento de energ\u00eda (PCS). Le ayudaremos a seleccionar la sonda ACP adecuada para pruebas de carga\/descarga, inversores y resistencia.<\/p>\r\n<div style=\"display:flex;justify-content:center;gap:30px;flex-wrap:wrap\">\r\n<a href=\"tel:+8613924199768\" class=\"btn-primary\">Ll\u00e1menos ahora<\/a>\r\n<a href=\"mailto:vasozks@gmail.com\" class=\"btn-outline\">Enviar correo electr\u00f3nico<\/a>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<\/body>\r\n<\/html>\r\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>PCS Current Probe for Energy Storage &amp; Battery Inverter | VASO Application PCS Current Probe for Energy Storage and Battery Inverter Testing Measure bidirectional PCS current, battery inverter current and high-power conversion waveforms with stable AC\/DC current probes built for long-duration testing. Energy storage PCS testing involves bidirectional power flow, high current levels and long [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":732,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-770","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/pages\/770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/comments?post=770"}],"version-history":[{"count":7,"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/pages\/770\/revisions"}],"predecessor-version":[{"id":807,"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/pages\/770\/revisions\/807"}],"up":[{"embeddable":true,"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/pages\/732"}],"wp:attachment":[{"href":"https:\/\/vasozk.com\/es\/wp-json\/wp\/v2\/media?parent=770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}