{"id":763,"date":"2026-06-25T03:21:38","date_gmt":"2026-06-25T03:21:38","guid":{"rendered":"https:\/\/vasozk.com\/?page_id=763"},"modified":"2026-07-01T12:57:37","modified_gmt":"2026-07-01T12:57:37","slug":"ac-dc-current-probe-for-power-electronics-lab-and-emc-testing","status":"publish","type":"page","link":"https:\/\/vasozk.com\/fr\/application\/ac-dc-current-probe-for-power-electronics-lab-and-emc-testing\/","title":{"rendered":"Sonde de courant AC\/DC pour laboratoire d'\u00e9lectronique de puissance et tests CEM"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"763\" class=\"elementor elementor-763\" data-elementor-settings=\"{&quot;element_pack_global_tooltip_width&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_padding&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true}}\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a41869 e-con-full e-flex e-con e-parent\" data-id=\"8a41869\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-168bdbf elementor-widget elementor-widget-html\" data-id=\"168bdbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<!DOCTYPE html>\r\n<html lang=\"en\">\r\n<head>\r\n<meta charset=\"UTF-8\">\r\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\r\n<title>AC\/DC Current Probe for Power Electronics Lab &amp; EMC | VASO<\/title>\r\n<style>\r\n*{margin:0;padding:0;box-sizing:border-box}\r\nbody{font-family:Arial,sans-serif;color:#555;line-height:1.8}\r\n.container{max-width:1200px;margin:0 auto}\r\n.section{padding:80px 60px}\r\n.label{font-size:14px;letter-spacing:3px;text-transform:uppercase;color:rgb(10,31,59);font-weight:600;margin-bottom:10px;display:block}\r\n.h1{font-size:48px;font-weight:600;color:#1a1a2e;margin-bottom:8px;line-height:1.2}\r\n.h1-sub{font-size:22px;font-weight:400;color:rgb(10,31,59);margin-bottom:20px;line-height:1.3}\r\n.h2{font-size:38px;font-weight:600;color:#1a1a2e;margin-bottom:30px;line-height:1.3}\r\n.h3{font-size:24px;font-weight:600;color:#1a1a2e;margin-bottom:20px}\r\n.p-lead{font-size:20px;color:rgb(10,31,59);font-weight:500;margin-bottom:30px}\r\n.p-body{font-size:16px;color:#555;line-height:1.85;max-width:900px;margin-bottom:20px}\r\n.divider{height:2px;width:100%;background:rgb(10,31,59);max-width:1200px;margin:0 auto}\r\n.card{background:#fff;border-radius:15px;padding:50px 40px;box-shadow:0 0 5px 3px rgba(0,0,0,.08)}\r\n.card-icon{font-size:48px;margin-bottom:20px;color:rgb(10,31,59)}\r\n.grid-2{display:grid;grid-template-columns:1fr 1fr;gap:40px}\r\n.checklist{list-style:none;padding:0;margin:0}\r\n.checklist li{font-size:15px;color:#555;line-height:1.8;margin-bottom:14px;padding-left:25px;position:relative}\r\n.checklist li::before{content:'\\2713';position:absolute;left:0;color:rgb(10,31,59);font-weight:bold}\r\n.btn-primary{display:inline-block;padding:15px 40px;background:rgb(10,31,59);color:#fff;text-decoration:none;border-radius:8px;font-weight:500;font-size:16px;transition:background .3s}\r\n.btn-primary:hover{background:#0d2548}\r\n.btn-outline{display:inline-block;padding:15px 40px;background:transparent;color:rgb(10,31,59);text-decoration:none;border:2px solid rgb(10,31,59);border-radius:8px;font-weight:500;font-size:16px;transition:all .3s}\r\n.btn-outline:hover{background:rgb(10,31,59);color:#fff}\r\ntable{width:100%;border-collapse:collapse;margin-top:20px;border-radius:12px;overflow:hidden;box-shadow:0 0 5px 3px rgba(0,0,0,.05)}\r\ntable thead th{text-align:left;padding:18px 24px;background:rgb(10,31,59);color:#fff!important;font-size:16px;font-weight:600}\r\ntable td{padding:16px 24px;border-bottom:1px solid #e8e8e8;font-size:15px;color:#1a1a2e;background:#fff}\r\n.faq-item{margin-bottom:30px}\r\n.faq-q{font-size:18px;font-weight:600;color:#1a1a2e;margin-bottom:10px}\r\n.faq-a{font-size:15px;color:#555;line-height:1.85}\r\n.model-card{text-align:center;padding:40px 30px}\r\n.model-card .model-name{font-size:20px;font-weight:700;color:#1a1a2e;margin-bottom:8px}\r\n.model-card .model-fit{font-size:14px;color:rgb(10,31,59);font-weight:600;margin-bottom:10px}\r\n.model-card .model-reason{font-size:14px;color:#777;line-height:1.6}\r\n.hero-img{width:100%;height:auto;border-radius:15px;box-shadow:0 0 10px 4px rgba(0,0,0,.1);margin-bottom:40px;display:block}\r\n.bw-bar{display:flex;align-items:center;gap:20px;margin-bottom:20px}\r\n.bw-bar-label{width:180px;font-size:14px;color:#1a1a2e;font-weight:600;text-align:right;flex-shrink:0}\r\n.bw-bar-track{flex:1;height:32px;background:#e8e8e8;border-radius:6px;overflow:hidden;position:relative}\r\n.bw-bar-fill{height:100%;background:linear-gradient(90deg,rgb(10,31,59),#1a5276);border-radius:6px;display:flex;align-items:center;padding-left:12px;color:#fff;font-size:13px;font-weight:600}\r\n.bw-bar-vs{background:linear-gradient(90deg,#b0b0b0,#d0d0d0)}\r\n.bw-bar-vs .bw-bar-fill{background:linear-gradient(90deg,#909090,#b0b0b0)}\r\n@media(max-width:768px){\r\n.grid-2{grid-template-columns:1fr}\r\n.section{padding:50px 30px}\r\n.h1{font-size:32px}\r\n.h2{font-size:28px}\r\n}\r\n<\/style>\r\n<\/head>\r\n<body>\r\n\r\n<!-- HERO -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\">\r\n<span class=\"label\">Application<\/span>\r\n<h1 class=\"h1\">Sonde de courant AC\/DC pour laboratoire d'\u00e9lectronique de puissance et tests CEM<\/h1>\r\n<p class=\"p-lead\">Capturez les formes d'onde du courant dans la R&amp;D en \u00e9lectronique de puissance, le d\u00e9veloppement du SiC, les alimentations \u00e0 d\u00e9coupage et le d\u00e9pannage CEM gr\u00e2ce aux sondes de courant ACP \u00e0 large bande passante.<\/p>\r\n<img decoding=\"async\" src=\"https:\/\/vasozk.com\/wp-content\/uploads\/2026\/07\/application-emc.webp\" alt=\"Laboratoire d&#039;\u00e9lectronique de puissance et CEM\" class=\"hero-img\">\r\n<p class=\"p-body\">Les laboratoires d'\u00e9lectronique de puissance ont besoin de sondes de courant capables d'afficher les d\u00e9tails de la forme d'onde, et pas seulement l'amplitude du courant. Les ing\u00e9nieurs passent fr\u00e9quemment d'une carte \u00e0 l'autre, entre convertisseurs, modules et bancs d'essai\u00a0; la rapidit\u00e9 d'installation et la robustesse sont donc essentielles.<\/p>\r\n<\/div>\r\n<\/section>\r\n\r\n<div class=\"divider\"><\/div>\r\n\r\n<!-- PAIN POINTS -->\r\n<section class=\"section\" style=\"background:#f8f9fa\">\r\n<div class=\"container\">\r\n<span class=\"label\">Points sensibles de l'industrie<\/span>\r\n<h2 class=\"h2\">D\u00e9fis rencontr\u00e9s dans les laboratoires de R&amp;D en \u00e9lectronique de puissance<\/h2>\r\n<p class=\"p-body\" style=\"margin-bottom:40px\">Les laboratoires d'\u00e9lectronique de puissance ont besoin de sondes de courant capables d'afficher les d\u00e9tails de la forme d'onde, et pas seulement l'amplitude du courant. Les ing\u00e9nieurs passent fr\u00e9quemment d'une carte \u00e0 l'autre, entre convertisseurs, modules et bancs d'essai\u00a0; la rapidit\u00e9 d'installation et la robustesse sont donc essentielles.<\/p>\r\n<div class=\"grid-2\">\r\n<div class=\"card\"><div class=\"card-icon\">\u26a1<\/div><h3 class=\"h3\">Fronts de commutation rapides<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Les commutations rapides dans les circuits SiC, GaN et IGBT mettent \u00e0 l'\u00e9preuve la bande passante des sondes.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83c\udf0a<\/div><h3 class=\"h3\">Ondulation et sonnerie<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Ondulations, oscillations et \u00e9v\u00e9nements transitoires courants n\u00e9cessitant une bande passante suffisante.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udd2c<\/div><h3 class=\"h3\">Points de test multiples<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Plusieurs points de test autour des cartes OBC, DC\/DC, onduleur et d'alimentation.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\u23f1<\/div><h3 class=\"h3\">Configuration lente<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Les adaptateurs secteur externes et la configuration manuelle des sondes ralentissent les tests quotidiens.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udca3<\/div><h3 class=\"h3\">Capteurs fragiles<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Capteurs haute fr\u00e9quence fragiles, faciles \u00e0 endommager lors d'une utilisation active en laboratoire.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83c\udf0a<\/div><h3 class=\"h3\">Localisation de la source EMC<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Difficult\u00e9 \u00e0 identifier les sources de bruit autour des trajets de courant \u00e0 haute fr\u00e9quence.<\/p><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- HOW IT HELPS -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\">\r\n<span class=\"label\">Solution<\/span>\r\n<h2 class=\"h2\">Comment les sondes ACP aident<\/h2>\r\n<p class=\"p-body\">Les sondes de la s\u00e9rie ACP sont con\u00e7ues pour la mesure des formes d'onde des courants alternatifs et continus \u00e0 l'aide d'un oscilloscope. Leur conception \u00e0 pince permet des tests non invasifs, tandis que l'alimentation directe de l'oscilloscope simplifie la configuration du banc d'essai.<\/p>\r\n<div class=\"grid-2\" style=\"margin-top:40px\">\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udcc8<\/div><h3 class=\"h3\">Capture \u00e0 haute fr\u00e9quence<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Capture de formes d'onde de courant haute fr\u00e9quence jusqu'\u00e0 DC\u201350 MHz avec l'ACP300.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udd0c<\/div><h3 class=\"h3\">Couverture \u00e9tendue<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Mesure du courant dans les alimentations, les onduleurs, les convertisseurs et les variateurs de vitesse.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\u2699<\/div><h3 class=\"h3\">Att\u00e9nuation automatique<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Prise en charge de la configuration automatique de l'att\u00e9nuation en fonction de la compatibilit\u00e9 de l'oscilloscope.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udd17<\/div><h3 class=\"h3\">C\u00e2blage r\u00e9duit<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">R\u00e9duction du c\u00e2blage de l'\u00e9tabli gr\u00e2ce \u00e0 l'alimentation directe de l'oscilloscope et \u00e0 l'alimentation USB Type-C.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udcaa<\/div><h3 class=\"h3\">Laboratoire durable<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Fournir une structure de capteur durable pour une utilisation fr\u00e9quente en laboratoire.<\/p><\/div>\r\n<div class=\"card\"><div class=\"card-icon\">\ud83d\udd2c<\/div><h3 class=\"h3\">D\u00e9pannage CEM<\/h3><p style=\"font-size:15px;color:#555;line-height:1.8\">Aider les ing\u00e9nieurs \u00e0 observer les trajets du courant \u00e0 haute fr\u00e9quence lors du d\u00e9pannage CEM.<\/p><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- BANDWIDTH COMPARISON -->\r\n<section class=\"section\" style=\"background:#f8f9fa\">\r\n<div class=\"container\">\r\n<span class=\"label\">Comparaison de la bande passante<\/span>\r\n<h2 class=\"h2\">Pourquoi la bande passante est importante pour les tests de laboratoire et de CEM<\/h2>\r\n<p class=\"p-body\">La bande passante de la sonde doit g\u00e9n\u00e9ralement \u00eatre de 3 \u00e0 5 fois sup\u00e9rieure \u00e0 la fr\u00e9quence la plus \u00e9lev\u00e9e de la composante \u00e0 observer. Pour les circuits \u00e0 commutation rapide, le mod\u00e8le ACP300 (DC\u201350 MHz) est souvent le premier \u00e0 \u00e9valuer.<\/p>\r\n<div style=\"max-width:650px;margin:30px auto\">\r\n<div class=\"bw-bar\"><div class=\"bw-bar-label\">ACP300<\/div><div class=\"bw-bar-track\"><div class=\"bw-bar-fill\" style=\"width:100%\">CC\u201350 MHz<\/div><\/div><\/div>\r\n<div class=\"bw-bar\"><div class=\"bw-bar-label\">ACP1000<\/div><div class=\"bw-bar-track\"><div class=\"bw-bar-fill\" style=\"width:80%\">CC\u201340 MHz<\/div><\/div><\/div>\r\n<div class=\"bw-bar\"><div class=\"bw-bar-label\">Pince amp\u00e8rem\u00e9trique typique<\/div><div class=\"bw-bar-track bw-bar-vs\"><div class=\"bw-bar-fill\" style=\"width:10%\">~5 MHz<\/div><\/div><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- RECOMMENDED MODELS -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\">\r\n<span class=\"label\">Mod\u00e8les recommand\u00e9s<\/span>\r\n<h2 class=\"h2\">Choisir la sonde de laboratoire appropri\u00e9e<\/h2>\r\n<div class=\"grid-2\">\r\n<div class=\"card model-card\"><div class=\"card-icon\">\ud83d\ude80<\/div><div class=\"model-name\">ACP300<\/div><div class=\"model-fit\">D\u00e9veloppement de SiC, analyse de formes d'onde haute fr\u00e9quence, d\u00e9bogage en laboratoire et d\u00e9pannage CEM<\/div><div class=\"model-reason\">Bande passante DC\u201350 MHz et plage de \u00b1300 A<\/div><\/div>\r\n<div class=\"card model-card\"><div class=\"card-icon\">\ud83c\udfc6<\/div><div class=\"model-name\">ACP1000<\/div><div class=\"model-fit\">Bancs de laboratoire \u00e0 courant \u00e9lev\u00e9, modules d'alimentation et mesure du bus principal<\/div><div class=\"model-reason\">Plage de \u00b11000 A avec une bande passante de DC \u00e0 40 MHz<\/div><\/div>\r\n<div class=\"card model-card\"><div class=\"card-icon\">\ud83d\udee0<\/div><div class=\"model-name\">Sonde de courant AC\/DC\uff08CA\/CC\uff09 personnalis\u00e9e<\/div><div class=\"model-fit\">Exigences particuli\u00e8res en mati\u00e8re d'acc\u00e8s \u00e0 la carte, de longueur de c\u00e2ble ou de port\u00e9e<\/div><div class=\"model-reason\">Configuration personnalis\u00e9e pour les \u00e9quipes de R&amp;D<\/div><\/div>\r\n<\/div>\r\n<p style=\"font-size:15px;color:#888;margin-top:30px;text-align:center\">L'ACP300 est le mod\u00e8le de r\u00e9f\u00e9rence pour l'analyse des formes d'onde en laboratoire et le d\u00e9pannage li\u00e9 \u00e0 la CEM. L'ACP1000 est plus adapt\u00e9 lorsque la plage de courant d\u00e9passe les exigences de l'ACP300.<\/p>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- TYPICAL TEST SCENARIOS -->\r\n<section class=\"section\" style=\"background:#f8f9fa\">\r\n<div class=\"container\">\r\n<span class=\"label\">Sc\u00e9narios de test<\/span>\r\n<h2 class=\"h2\">Sc\u00e9narios de test typiques<\/h2>\r\n<div class=\"grid-2\">\r\n<div class=\"card\"><ul class=\"checklist\"><li>Capture de la forme d'onde du courant de commutation des MOSFET et IGBT SiC<\/li><li>mesure du courant du convertisseur r\u00e9sonant LLC<\/li><li>analyse du courant de l'inductance PFC<\/li><li>Tests d'ondulation de courant des convertisseurs OBC et DC\/DC<\/li><\/ul><\/div>\r\n<div class=\"card\"><ul class=\"checklist\"><li>D\u00e9pannage des alimentations de serveurs, des onduleurs et des alimentations industrielles<\/li><li>Localisation des sources de bruit CEM autour des trajets de courant haute fr\u00e9quence<\/li><li>Tests de courant des bras de pont d'entra\u00eenement de moteur et d'onduleur<\/li><\/ul><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- PARAMETERS -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\">\r\n<span class=\"label\">Caract\u00e9ristiques<\/span>\r\n<h2 class=\"h2\">Param\u00e8tres et avantages<\/h2>\r\n<table><thead><tr><th>Capacit\u00e9<\/th><th>Avantages de la s\u00e9rie ACP<\/th><\/tr><\/thead><tbody>\r\n<tr><td>Bande passante<\/td><td>Jusqu'\u00e0 DC\u201350 MHz avec ACP300<\/td><\/tr>\r\n<tr><td>Gamme actuelle<\/td><td>\u00b1300 A pour ACP300 ; \u00b11000 A pour ACP1000<\/td><\/tr>\r\n<tr><td>Temps de lever<\/td><td>ACP300 \u2264 7 ns ; ACP1000 \u2264 8,5 ns (donn\u00e9es internes du produit)<\/td><\/tr>\r\n<tr><td>Pr\u00e9cision<\/td><td>Valeur typique \u00b11 %, valeur de garantie \u00b13 %<\/td><\/tr>\r\n<tr><td>Alimentation \u00e9lectrique<\/td><td>Alimentation directe de l'oscilloscope ou alimentation USB Type-C<\/td><\/tr>\r\n<tr><td>Configuration d'att\u00e9nuation<\/td><td>Automatique, selon la compatibilit\u00e9 de l'oscilloscope<\/td><\/tr>\r\n<tr><td>Temp\u00e9rature de fonctionnement<\/td><td>\u221240 \u00b0C \u00e0 +85 \u00b0C<\/td><\/tr>\r\n<tr><td>Durabilit\u00e9<\/td><td>Structure de capteur stable pour une manipulation fr\u00e9quente en laboratoire<\/td><\/tr>\r\n<\/tbody><\/table>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- FAQ -->\r\n<section class=\"section\" style=\"background:#f8f9fa\">\r\n<div class=\"container\">\r\n<span class=\"label\">FAQ<\/span>\r\n<h2 class=\"h2\">Foire aux questions<\/h2>\r\n<div class=\"faq-item\"><p class=\"faq-q\">Quel mod\u00e8le d'ACP est le mieux adapt\u00e9 aux laboratoires d'\u00e9lectronique de puissance\u00a0?<\/p><p class=\"faq-a\">L'ACP300 est recommand\u00e9 pour la plupart des analyses de formes d'onde en laboratoire, car il offre une bande passante de 50 MHz (DC-50 MHz) et une plage de courant de \u00b1300 A. L'ACP1000 est recommand\u00e9 lorsqu'une plage de courant plus \u00e9lev\u00e9e est requise.<\/p><\/div>\r\n<div class=\"faq-item\"><p class=\"faq-q\">Les sondes ACP peuvent-elles aider au d\u00e9pannage CEM\u00a0?<\/p><p class=\"faq-a\">Oui. Les sondes ACP peuvent aider les ing\u00e9nieurs \u00e0 observer les trajets de courant \u00e0 haute fr\u00e9quence, l'ondulation et le comportement du courant li\u00e9 \u00e0 la commutation lors du d\u00e9pannage CEM.<\/p><\/div>\r\n<div class=\"faq-item\"><p class=\"faq-q\">Les sondes ACP peuvent-elles \u00eatre aliment\u00e9es par un oscilloscope\u00a0?<\/p><p class=\"faq-a\">Oui. Les sondes ACP prennent en charge l'alimentation directe de l'oscilloscope et l'alimentation USB Type-C, ce qui contribue \u00e0 r\u00e9duire le c\u00e2blage de l'\u00e9tabli.<\/p><\/div>\r\n<div class=\"faq-item\"><p class=\"faq-q\">Comment choisir la bande passante de la sonde de courant\u00a0?<\/p><p class=\"faq-a\">La bande passante de la sonde doit g\u00e9n\u00e9ralement \u00eatre de 3 \u00e0 5 fois la fr\u00e9quence la plus \u00e9lev\u00e9e de la composante \u00e0 observer. Pour les circuits \u00e0 commutation rapide, l'ACP300 est souvent le premier mod\u00e8le \u00e0 \u00e9valuer.<\/p><\/div>\r\n<div class=\"faq-item\"><p class=\"faq-q\">Des sondes personnalis\u00e9es sont-elles disponibles pour les laboratoires de R&amp;D\u00a0?<\/p><p class=\"faq-a\">Oui. La plage de courant, la bande passante, la taille des m\u00e2choires, la longueur du c\u00e2ble et la configuration de l'interface peuvent \u00eatre personnalis\u00e9es pour les bancs de R&amp;D sp\u00e9cifiques.<\/p><\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<!-- CTA -->\r\n<section class=\"section\" style=\"background:#fff\">\r\n<div class=\"container\" style=\"text-align:center\">\r\n<h3 class=\"h3\" style=\"font-size:28px\">Pr\u00eat \u00e0 \u00e9quiper votre laboratoire ?<\/h3>\r\n<p class=\"p-body\" style=\"max-width:800px;margin:0 auto 30px\">Contactez VASO d\u00e8s aujourd'hui pour trouver la sonde de courant ACP adapt\u00e9e \u00e0 vos besoins en R&amp;D \u00e9lectronique de puissance ou \u00e0 votre banc d'essai CEM. Installation rapide, acquisition de formes d'onde fiable, conception robuste pour une utilisation en laboratoire.<\/p>\r\n<div style=\"display:flex;justify-content:center;gap:30px;flex-wrap:wrap\">\r\n<a href=\"tel:+8613924199768\" class=\"btn-primary\">Appelez-nous maintenant<\/a>\r\n<a href=\"mailto:vasozks@gmail.com\" class=\"btn-outline\">Envoyer un e-mail<\/a>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n\r\n<\/body>\r\n<\/html>\r\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>AC\/DC Current Probe for Power Electronics Lab &amp; EMC | VASO Application AC\/DC Current Probe for Power Electronics Lab and EMC Testing Capture current waveforms in power electronics R&amp;D, SiC development, switching power supplies and EMC troubleshooting with high-bandwidth ACP current probes. Power electronics labs need current probes that can show waveform details, not only [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":732,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-763","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/pages\/763","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/comments?post=763"}],"version-history":[{"count":7,"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/pages\/763\/revisions"}],"predecessor-version":[{"id":798,"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/pages\/763\/revisions\/798"}],"up":[{"embeddable":true,"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/pages\/732"}],"wp:attachment":[{"href":"https:\/\/vasozk.com\/fr\/wp-json\/wp\/v2\/media?parent=763"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}